Infusion & Drivers
 
     
J1346 - Volumetric Infusion Pump
  Features & Specifications
     
J1346 - Volumetric Infusion Pump
 

Dimension; 1.46 x 1.93 x 95mm, Weight 1.6 kg
Flow Rates; 0.1~1500ml/h
VTBI; 0.1~999.9ml increment is 0.1ml)
VTBI; 1000~9999ml increment is 1.0ml)
Accuracy: +/- 5%; KVO: 0.5ml/h; Bolus Rate: 0.10-1500ml/h
Occlusion: Low (150+125mmHg(20kPa)
Occlusion: Medium (525+125mmHg(70kPa)
Occlusion: High (900+1810mmHg (120kPa)

Screen is 2.5 LCD; self test system; keypad lock; air bubble detection.

Alarms: VTBI done/near done; KVO finish; bottle/bag empty; door open; set not installed; occlusion; air in line; drop error; system error; battery low; AC power disconnection

 

     
     
J1379 - syringe driver; basic, single channel
  Features & Specifications
     
J1379 - syringe driver; basic, single channel   Dimension; 360 x 145 x 123mm, Weight 1.95 kg
Syringe Sizes; 5, 10,20, 30, 50/60ml
Flow Rates; 5ml(0.1~150ml/h)10ml (0.1~300ml/h)20ml (0.1~600ml/h)
Flow Rates cont; 30ml (0.1~900ml/h) 50/60ml (0.1~1500ml/h)
VTBI; 0.1~999.9ml increment is 0.1ml)
VTBI; 1000~9999ml increment is 1.0ml)
Accuracy: +/- 2%; KVO: 0.5ml/h; Bolus Rate: 0.10-1500ml/h
Occlusion: Low (300+125mmHg(40kPa)
Occlusion: Medium (525+125mmHg(70kPa)
Occlusion: High (900+1810mmHg (120kPa)

Automatic sryinge recognition; 2.5 LCD screen; keypad lock; self test syestem, alarm system includes: VTBI done / near done; KVO finish; plus all other standard alarm mechanisms
Pre set syringe brand: Braun/Terumo etc.

     
J1380 - syringe driver; mass unit
  Features & Specifications
     
J1380 - syringe driver; mass unit   Dimension; 360 x 145 x 123mm, Weight 1.95 kg
Syringe Sizes; 5, 10,20, 30, 50/60ml
Infusion Modes: Rate Mode; Time Mode; Body weight mode.
Flow Rates; 5ml(0.1~150ml/h)10ml (0.1~300ml/h)20ml (0.1~600ml/h)
Flow Rates cont; 30ml (0.1~900ml/h) 50/60ml (0.1~1500ml/h)
VTBI; 0.1~999.9ml increment is 0.1ml)
VTBI; 1000~9999ml increment is 1.0ml)
Accuracy: +/- 2%; KVO: 0.5ml/h; Bolus Rate: 0.10-1500ml/h
Occlusion: Low (300+125mmHg(40kPa)
Occlusion: Medium (525+125mmHg(70kPa)
Occlusion: High (900+1810mmHg (120kPa)

Automatic sryinge recognition; 3.0 LCD screen; keypad lock; self test syestem, alarm system includes: VTBI done / near done; KVO finish; Drug Library (200 drugs); history of records plus all other standard alarm mechanisms
Pre set syringe brand: Braun/Terumo etc.
     